HP iLO Check Reference
All parameters, thresholds, and configuration options for the HP iLO check in octoja.
Written By Erdinc Akay
Last updated About 2 months ago
HP iLO Check Reference
The HP iLO Check monitors HPE ProLiant servers via their iLO management interface using SNMP and captures temperature, fans, power supplies, hard drives, and memory.
Configuration fields
Collected metrics
- Server model and serial number
- Overall health status
- Ambient and component temperatures
- Fan speeds and status
- Power supply status (OK, degraded, failed)
- Physical hard drive status
- Memory module status (Not Present, Not Supported, Ok, Degraded, Failed)
Platform support
The check runs on the agent device and connects to the iLO interface via SNMP.
Notes
- Requires an HPE ProLiant server with iLO (any version) and SNMP enabled on the iLO management processor.
- The check uses standard Compaq/HPE Health (CPQHLTH, CPQIDA, CPQSINFO) MIB OIDs, which are present on iLO 2 and later.
- Fan and power supply states map automatically (Degraded → warning, Failed → critical) — no configurable thresholds. Temperature thresholds are configurable, but only apply to sensors whose name begins with "Ambient" — they have no effect on CPU, System, or Memory temperature sensors.
See also: Configure an HP iLO Check