Skip to main content
Hardware

Adaptec RAID (SNMP)

Monitor RAID health, controllers, arrays, logical disks, SMART and batteries of an Adaptec RAID controller via SNMP.

The Adaptec RAID (SNMP) check monitors an Adaptec RAID controller through the SNMP service of the Adaptec storage agent (Adaptec Storage Manager or maxView Storage Manager): overall health, controller operation and controller overall health, the zero-maintenance module (ZMM), arrays, logical disks, drive SMART status and the controller battery. It runs network-based on an octoja agent on Windows, Linux, or macOS (x64 and Arm64) that can reach the monitored device, every 5 minutes by default.

To monitor Broadcom/MegaRAID controllers, use the RAID Status check with StorCLI instead.

Prerequisites

  • The device with the Adaptec controller runs the Adaptec storage agent with SNMP enabled (v1, v2c or v3).
  • The executing octoja agent can reach that device over UDP (port 161 by default).
  • You need the Monitoring Check Management permission.

Steps

  1. Go to Devices and open the device whose agent can reach the Adaptec SNMP service.
  2. Click the Checks tab → Add Check → Adaptec RAID (SNMP).
  3. Enter the hostname or IP address of the device running the Adaptec storage agent under Host, and provide the SNMP credentials.
  4. Click Add Check.

You can also assign the check to a network device; octoja then fills Host with that device's IP address, and the agent set as Monitoring device runs the query. SNMP settings stored on the network device take precedence over those in the check.

Settings

FieldTypeRequiredDefaultDescription
HostTextYes—Hostname or IP address of the device running the Adaptec storage agent with SNMP enabled
SNMP versionSelect (v1 / v2c / v3)Yesv2cSNMP protocol version
UDP portNumberYes161UDP port of the SNMP service (1–65535)
SNMP communityPasswordYespublicOnly shown for v1 and v2c
SNMPv3 userTextYes—Only shown for v3
Authentication protocolSelect (None / SHA-1 / SHA-256)NoNoneOnly shown for v3
Authentication passwordPasswordYes—Shown when an authentication protocol is selected
Privacy protocolSelect (None / AES-128 / AES-192 / AES-256)NoNoneShown when an authentication protocol is selected
Privacy passwordPasswordYes—Shown when a privacy protocol is selected

Results

The check evaluates every reported component separately. The overall result is the worst status across all components.

ComponentOKWarningCritical
Overall health, controller operation, controller overall health, array status, logical diskokayunknown, other, warningfailure
Zero-maintenance module (ZMM)okay, notInstalledunknown, chargingfailed
Array healthoptimalunknown, other, quickInited, impacted, compacteddegraded, failed
SMARTokay, notSupportedunknown, notEnablederrorPredicted
Controller batteryokay, notApplicable, notInstalledunknown, other, charging, discharging, maintenance, chargingDisabledfailed

Other outcomes:

ConditionStatus
Host missing, invalid SNMP version or UDP portFailure
Overall health missing from the responseFailure
A component reports an invalid or unmapped valueFailure
The SNMP connection or reading a component table fails, for example because of a timeoutFailure; components already read stay in the result
The device does not support an optional component tableNo result for that component

The result names the component with the worst status, with its index, reported value and OID, plus the error message where applicable.

See also: RAID Status · Assign checks with config packages