Skip to main content
Storage & files

Huawei OceanStor Dorado V6

Monitor hardware health, capacity, controller load, temperatures, selected ports and LUN latency of your Huawei OceanStor Dorado V6 via SNMP.

The Huawei OceanStor Dorado V6 check monitors a Huawei OceanStor Dorado V6 storage system via SNMP: the hardware health of storage pools, disks, controllers, power supplies, fans, batteries and enclosures, the used capacity of storage pools, controller CPU and memory usage, disk and enclosure temperatures, explicitly selected Ethernet and FC ports, and LUN latency and IOPS. It runs network-based on an octoja agent on Windows, Linux, or macOS (x64 and Arm64) that can reach the storage system over the network, every 5 minutes by default.

Prerequisites

  • SNMP is enabled on the OceanStor system (v2c or v3), and the executing agent can reach it on the SNMP port.
  • You need the Monitoring Check Management permission.

Steps

  1. Go to Devices and open the device whose agent can reach the storage system.
  2. Click the Checks tab → Add Check → Huawei OceanStor Dorado V6.
  3. Enter the storage system under Host and provide the SNMP credentials.
  4. Under Ports to monitor, enter the exact location names of the ports to monitor. Without entries, the check monitors no ports.
  5. Adjust the thresholds if needed and click Add Check.

You can also assign the check to a network device; octoja then fills Host with that device's IP address, and the agent set as Monitoring device runs the query. SNMP settings stored on the network device take precedence over those in the check.

Settings

FieldTypeRequiredDefaultDescription
HostTextYes—Hostname or IP address of the Huawei OceanStor system
SNMP portNumberYes161UDP port of the SNMP agent
SNMP versionSelect (v2c / v3)Yesv2cSNMP protocol version
CommunityPasswordNopublicOnly shown for v2c
SNMPv3 userTextNo—Only shown for v3
Authentication protocolSelect (None / SHA-1 / SHA-256)NoNoneOnly shown for v3
Authentication passwordPasswordNo—Shown when an authentication protocol is selected
Privacy protocolSelect (None / AES-128 / AES-192 / AES-256)NoNoneShown when an authentication protocol is selected
Privacy passwordPasswordNo—Shown when a privacy protocol is selected
Ports to monitorListNoEmptyExact location names of Ethernet or FC ports. Only these ports are monitored; no ports are selected automatically. An empty list disables port monitoring
CPU warning (%)Number (0–100)No80Controller CPU usage at which a warning is raised
CPU critical (%)Number (0–100)No95CPU usage at which the result becomes critical
Memory warning (%)Number (0–100)No85Controller memory usage at which a warning is raised
Memory critical (%)Number (0–100)No95Memory usage at which the result becomes critical
Used capacity warning (%)Number (0–100)No80Used capacity of a storage pool at which a warning is raised
Used capacity critical (%)Number (0–100)No90Used capacity at which the result becomes critical
Disk temperature warning (°C)Number (0–200)No55Disk temperature at which a warning is raised
Disk temperature critical (°C)Number (0–200)No65Disk temperature at which the result becomes critical
Enclosure temperature warning (°C)Number (0–200)No40Enclosure temperature at which a warning is raised
Enclosure temperature critical (°C)Number (0–200)No50Enclosure temperature at which the result becomes critical
LUN latency warning (ms)Number (0 or more)No2LUN latency at which a warning is raised
LUN latency critical (ms)Number (0 or more)No5LUN latency at which the result becomes critical

The editor lists the thresholds under Alert thresholds. They apply immediately to each reading, without a sustained-duration requirement, as soon as the reading reaches them. If a warning threshold is higher than its critical threshold, the check swaps the two. If a threshold is outside its allowed range, the check reports Failure.

Results

The overall result is the worst status across all readings.

ConditionStatus
A component's health is Normal or ConsistentOK
A component's health is Fault, Bad sectors, Bit errors, Inconsistent, No input, No redundant link, or OfflineCritical
A component's health reports another value, for example Pre-fail, Degraded, or Low batteryWarning
A reading reaches its critical thresholdCritical
A reading reaches its warning thresholdWarning
A reading that has a threshold is unavailableWarning
A selected port is missing, has a link speed of zero, or its FC SFP is offlineCritical
The link speed of a selected port is unavailableWarning
Host missing, invalid settings, system unreachable, SNMP error, or no monitoring data returnedFailure
  • The check uses SNMP polling only. It does not evaluate traps, error counters, or running statuses.
  • The check calculates a storage pool's used capacity from its total and free capacity.
  • IOPS per LUN are shown for information only and are not evaluated. LUNs appear with their SNMP index.

The result shows the number of checked values and lists every value that is not OK, each with component, metric, value and, where applicable, threshold.

See also: Assign checks with config packages