Fujitsu iRMC status
Monitor the hardware of your Fujitsu PRIMERGY servers through the iRMC via Redfish, including memory, RAID and the system event log.
The Fujitsu iRMC status check monitors Fujitsu PRIMERGY hardware through the iRMC's Redfish interface. It checks overall health, processors, memory, temperatures, fans, power supplies, RAID controllers, volumes, drives and the system event log, independently of the server operating system. It runs every 15 minutes by default.
Prerequisites
- An iRMC supporting Redfish.
- A dedicated iRMC user with read access.
- A device running the octoja agent that can reach the iRMC over HTTPS, and permission to assign checks. For a device without an agent, its monitoring device executes the check.
Steps
- Open the device and choose Checks → Add Check → Fujitsu iRMC status.
- Enter iRMC host, iRMC user and iRMC password. Use the iRMC management address, not the server operating-system address. An agentless assignment uses the device address as its host.
- Check HTTPS port and Accept self-signed certificate. Turn the switch off when the iRMC has a certificate the monitoring device can validate and trust.
- Leave Check storage and Check system event log enabled if you need those findings.
- Click Add Check. After the next run, hardware values and findings appear in the check.
Settings
Temperatures are evaluated against the warning and critical thresholds the iRMC reports for each sensor. This check has no custom thresholds.
Results
Overall status follows the most severe finding. Empty slots for memory modules, fans and power supplies are not reported as faults.
A successful connection alone does not confirm complete hardware health. The iRMC's internal log (InternalEventLog) is not evaluated.
Troubleshooting
For connection or authentication failures, check reachability and port from the executing agent device, the credentials and the iRMC's Redfish support. Compare a hardware finding with the iRMC web interface. Monitoring does not repair hardware or acknowledge system event log entries.
A critical entry without a timestamp cannot be matched to a time window, so it is reported on every run until it is removed from the iRMC system event log.
FAQ
Which Fujitsu check fits my server?
Which Fujitsu check fits my server?
Fujitsu ServerView Health (SNMP) queries the ServerView agents in the server operating system over SNMP. Fujitsu iRMC status queries the iRMC directly via Redfish and needs no ServerView agents in the operating system. It also reports hardware health when the operating system is not running.
Was this helpful?
More in Hardware
CPU TemperatureDell iDRACDisk PresenceFujitsu ServerView Health (SNMP)Still need help? Ask the team