Skip to main content
Hardware

Fujitsu iRMC status

Monitor the hardware of your Fujitsu PRIMERGY servers through the iRMC via Redfish, including memory, RAID and the system event log.

The Fujitsu iRMC status check monitors Fujitsu PRIMERGY hardware through the iRMC's Redfish interface. It checks overall health, processors, memory, temperatures, fans, power supplies, RAID controllers, volumes, drives and the system event log, independently of the server operating system. It runs every 15 minutes by default.

Prerequisites

  • An iRMC supporting Redfish.
  • A dedicated iRMC user with read access.
  • A device running the octoja agent that can reach the iRMC over HTTPS, and permission to assign checks. For a device without an agent, its monitoring device executes the check.

Steps

  1. Open the device and choose Checks → Add Check → Fujitsu iRMC status.
  2. Enter iRMC host, iRMC user and iRMC password. Use the iRMC management address, not the server operating-system address. An agentless assignment uses the device address as its host.
  3. Check HTTPS port and Accept self-signed certificate. Turn the switch off when the iRMC has a certificate the monitoring device can validate and trust.
  4. Leave Check storage and Check system event log enabled if you need those findings.
  5. Click Add Check. After the next run, hardware values and findings appear in the check.

Settings

FieldTypeRequiredDefaultDescription
iRMC hoststringYes—iRMC management address, not the server operating-system address
iRMC userstringYes—Dedicated user with read access
iRMC passwordpasswordYes—Password of the iRMC user
HTTPS portintegerNo443HTTPS port of the iRMC web interface
Accept self-signed certificatebooleanNoonBypasses certificate validation
Check storagebooleanNoonChecks RAID controllers, volumes, drives and drive failure prediction
Check system event logbooleanNoonEvaluates critical system event log entries within the window
Event log window (hours)integerNo24Window for the system event log evaluation; visible when the system event log is checked

Temperatures are evaluated against the warning and critical thresholds the iRMC reports for each sensor. This check has no custom thresholds.

Results

Overall status follows the most severe finding. Empty slots for memory modules, fans and power supplies are not reported as faults.

FindingStatus
Overall health, processors, chassis or the iRMC itself reports a degraded stateWarning or critical, as reported by the iRMC
Failed memory moduleWarning or critical with the module name. When the iRMC provides no module details, the health of the memory as a whole is reported.
Fan, power supply, RAID controller, volume or drive degradedWarning or critical, as reported by the iRMC
Temperature reaches the iRMC warning or critical thresholdWarning or critical respectively
Power supply redundancy degradedWarning
Drive failure predictedCritical
Server powered offWarning
Critical system event log entry within the windowWarning; at most the 20 newest entries are shown
No temperature or fan dataWarning
iRMC unreachable, credentials rejected or no Redfish responseError

A successful connection alone does not confirm complete hardware health. The iRMC's internal log (InternalEventLog) is not evaluated.

Troubleshooting

For connection or authentication failures, check reachability and port from the executing agent device, the credentials and the iRMC's Redfish support. Compare a hardware finding with the iRMC web interface. Monitoring does not repair hardware or acknowledge system event log entries.

A critical entry without a timestamp cannot be matched to a time window, so it is reported on every run until it is removed from the iRMC system event log.

FAQ

Fujitsu ServerView Health (SNMP) queries the ServerView agents in the server operating system over SNMP. Fujitsu iRMC status queries the iRMC directly via Redfish and needs no ServerView agents in the operating system. It also reports hardware health when the operating system is not running.