TP-Link EAP

Monitor Omada EAP connected clients and required uplinks over SNMP, with firmware prerequisites and verification guidance.

The TP-Link EAP check monitors an Omada access point's SNMP availability, connected-client count, and selected uplinks. It runs every 5 minutes by default on an octoja agent with Windows, Linux, or macOS, on x64 or ARM64. It does not monitor radio health, CPU, memory, or controller adoption.

Prerequisites

  • An online octoja agent that can reach the access point's management address on UDP 161, or your configured SNMP port.
  • SNMP enabled on the access point, read-only v1, v2c or v3 credentials, and access allowed from the executing agent. Match the version supported by the device firmware; query the access point, not the Omada controller.
  • A verified, working client-count scalar on your exact model, hardware revision, and firmware. The check uses 1.3.6.1.4.1.11863.10.1.1.1.0 from EAP-CLIENT-MIB. Check TP-Link's MIB downloads and verify the live value before relying on client-load alerts.

EAP610 v3 firmware caveat: TP-Link's support thread records client-count problems on firmware 1.3.2 and zero readings despite connected clients on a 1.4.0 beta. Users reported a fix with the support-provided build EAP610v3_1.3.90_[20230821-rel62568]_up_signed. This is not a general minimum-version rule, a recommendation to install that historical build, or a compatibility guarantee for other models. Obtain suitable current firmware for your hardware revision from TP-Link and verify the count afterward.

The check cannot distinguish a firmware-generated false zero from a genuinely empty access point and does not automatically check firmware compatibility. A zero value can therefore produce OK on affected firmware. Do not rely on client-load alerts until the verification below passes.

Prefer authenticated, encrypted SNMPv3 where supported. A v1/v2c community travels unencrypted; replace the public default on the device and in octoja.

Steps

  1. Open the executing device under Devices, then Checks → Add Check, and select TP-Link EAP. See Activate your first check for the assignment workflow.
  2. Enter the access point's management address under Host / IP and matching SNMP credentials.
  3. Set Client count warning and Client count critical for your site's intended load. Optionally enter exact IF-MIB ifDescr names or ifIndex values under Required links.
  4. Click Add Check, then verify the first result before relying on alerts.

You can instead register the access point as an agentless network device with a monitoring asset. Add the check to the access point's Checks tab. Its own IP address is used automatically; when SNMP is configured on the network device, its connection settings override check-level SNMP fields. Client thresholds and required links remain check settings.

Verify the client count

  1. Compare Connected clients in the check result with the current count in the access point or Omada controller while you know clients are connected.
  2. Connect or disconnect a test Wi-Fi client and compare again after the next check run. Allow for the difference in polling times; confirm that the count changes plausibly, rather than requiring identical snapshots.
  3. If the scalar stays at zero despite connected clients, treat client-load monitoring as unavailable. Check firmware compatibility with TP-Link, apply a suitable fix, and repeat verification. A successful SNMP connection test or a green result alone is not sufficient.
  4. Repeat this verification after firmware changes. Do not attempt to fix a false zero by lowering thresholds or treating every zero as a fault: an empty access point is a legitimate state.

Settings

FieldTypeRequiredDefaultDescription
Host / IPStringYes—Access point management address, without https://.
SNMP versionSelectNov2cv1, v2c or v3, matching the device firmware. Choose v1 only if the device does not offer v2c.
SNMP portIntegerNo161UDP port, from 1 to 65535.
Community (v1/v2c)StringNopublicRead community; visible for v1 and v2c.
Username (v3)StringFor v3—SNMPv3 user.
Authentication protocolSelectNoSHA-1None, SHA-1, or SHA-256; visible for v3.
Authentication passwordPasswordWith authentication—Required unless authentication is None.
Privacy protocolSelectNoAES-128None, AES-128, AES-192, or AES-256; visible with authentication.
Privacy passwordPasswordWith encryption—Required unless privacy is None.
Required linksList of stringsNoEmptyExact IF-MIB ifDescr names, case-sensitive, or ifIndex values. Unselected ports do not alarm.
Client count warning / Client count criticalIntegerNo100 / 200Total client-count thresholds, each at least 1; not per-radio limits or universal device-capacity recommendations.

Thresholds are inclusive. If warning exceeds critical, the check orders the pair from lower to higher. Selecting None for authentication disables encryption and hides privacy fields. MD5 and DES are not offered.

Results

The highest severity determines the overall result. SNMP uptime is displayed in days.

ResultMeaning and next action
OKThe returned client count is below thresholds and selected links are up. Zero clients is healthy only if the firmware's value is trustworthy; follow the verification above.
WarningThe warning threshold was reached, client count is missing/invalid, or a selected link's status is unavailable. Check firmware/MIB support and the reported interface.
CriticalThe critical client threshold was reached, a required link is missing/down, or SNMP did not respond. Check client load or the affected uplink; for no response, check UDP access, community, and device access rules.
ErrorConfiguration, SNMP authentication/access, or protocol processing failed. Read the error and check credentials, enabled protocols, and input values.

FAQ

No. Missing or invalid data produces Warning, not a zero metric. Firmware that returns a valid but incorrect zero is a different case: the check accepts that value. Verify it against the device/controller before relying on the result.